Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.248 IF 3.248
  • IF 5-year value: 3.650 IF 5-year 3.650
  • CiteScore value: 3.37 CiteScore 3.37
  • SNIP value: 1.253 SNIP 1.253
  • SJR value: 1.869 SJR 1.869
  • IPP value: 3.29 IPP 3.29
  • h5-index value: 47 h5-index 47
  • Scimago H index value: 60 Scimago H index 60
Volume 10, issue 3 | Copyright
Atmos. Meas. Tech., 10, 1241-1258, 2017
https://doi.org/10.5194/amt-10-1241-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 30 Mar 2017

Research article | 30 Mar 2017

Measurement of ambient NO3 reactivity: design, characterization and first deployment of a new instrument

Jonathan M. Liebmann, Gerhard Schuster, Jan B. Schuladen, Nicolas Sobanski, Jos Lelieveld, and John N. Crowley Jonathan M. Liebmann et al.
  • Atmospheric Chemistry Department, Max-Planck-Institut für Chemie, 55128 Mainz, Germany

Abstract. We describe the first instrument for measurement of the rate constant (s−1) for reactive loss (i.e., the total reactivity) of NO3 in ambient air. Cavity-ring-down spectroscopy is used to monitor the mixing ratio of synthetically generated NO3 ( ≈ 30–50pptv) after passing through a flow-tube reactor with variable residence time (generally 10.5s). The change in concentration of NO3 upon modulation of the bath gas between zero air and ambient air is used to derive its loss rate constant, which is then corrected for formation and decomposition of N2O5 via numerical simulation. The instrument is calibrated and characterized using known amounts of NO and NO2 and tested in the laboratory with an isoprene standard. The lowest reactivity that can be detected (defined by the stability of the NO3 source, instrumental parameters and NO2 mixing ratios) is 0.005s−1. An automated dilution procedure enables measurement of NO3 reactivities up to 45s−1, this upper limit being defined mainly by the dilution accuracy. The typical total uncertainty associated with the reactivity measurement at the center of its dynamic range is 16%, though this is dependent on ambient NO2 levels. Results from the first successful deployment of the instrument at a forested mountain site with urban influence are shown and future developments outlined.

Please read the corrigendum first before accessing the article.
Publications Copernicus
Download
Notice on corrigendum

The requested paper has a corresponding corrigendum published. Please read the corrigendum first before downloading the article.

Short summary
We describe the first instrument for measurement of the rate constant for reactive loss (i.e. the total reactivity) of NO3 in ambient air. This is essentially a measureement of the lifetime of NO3 and will help assess the role of NO3 and N2O5 in conversion of reactive nitrogen oxides to reservoir species in the troposphere.
We describe the first instrument for measurement of the rate constant for reactive loss (i.e....
Citation
Share