Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.400 IF 3.400
  • IF 5-year value: 3.841 IF 5-year
    3.841
  • CiteScore value: 3.71 CiteScore
    3.71
  • SNIP value: 1.472 SNIP 1.472
  • IPP value: 3.57 IPP 3.57
  • SJR value: 1.770 SJR 1.770
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 70 Scimago H
    index 70
  • h5-index value: 49 h5-index 49
Volume 10, issue 6
Atmos. Meas. Tech., 10, 2299–2311, 2017
https://doi.org/10.5194/amt-10-2299-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.
Atmos. Meas. Tech., 10, 2299–2311, 2017
https://doi.org/10.5194/amt-10-2299-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 22 Jun 2017

Research article | 22 Jun 2017

Forest Fire Finder – DOAS application to long-range forest fire detection

Rui Valente de Almeida and Pedro Vieira
Viewed  
Total article views: 1,446 (including HTML, PDF, and XML)
HTML PDF XML Total BibTeX EndNote
570 842 34 1,446 45 38
  • HTML: 570
  • PDF: 842
  • XML: 34
  • Total: 1,446
  • BibTeX: 45
  • EndNote: 38
Views and downloads (calculated since 14 Nov 2016)
Cumulative views and downloads (calculated since 14 Nov 2016)
Viewed (geographical distribution)  
Total article views: 1,385 (including HTML, PDF, and XML) Thereof 1,382 with geography defined and 3 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Cited  
Saved (final revised paper)  
No saved metrics found.
Saved (discussion paper)  
No saved metrics found.
Discussed (final revised paper)  
No discussed metrics found.
Discussed (discussion paper)  
No discussed metrics found.
Latest update: 16 Sep 2019
Publications Copernicus
Download
Short summary
This paper presents the Forest Fire Finder (FFF) System, a long range forest fire detection system. It works by detecting a smoke column above the horizon, by analysing the light that goes through it. In the article, you will find a technical description and an analysis of the behaviour of 13 of these devices, which were installed in a Portuguese national park. We conclude that the deployed FFF network managed to detect more that 200 fires, proving the system to be effective in fire detection.
This paper presents the Forest Fire Finder (FFF) System, a long range forest fire detection...
Citation