Journal metrics

Journal metrics

  • IF value: 3.248 IF 3.248
  • IF 5-year value: 3.650 IF 5-year 3.650
  • CiteScore value: 3.37 CiteScore 3.37
  • SNIP value: 1.253 SNIP 1.253
  • SJR value: 1.869 SJR 1.869
  • IPP value: 3.29 IPP 3.29
  • h5-index value: 47 h5-index 47
  • Scimago H index value: 60 Scimago H index 60
Atmos. Meas. Tech., 10, 2323-2335, 2017
https://doi.org/10.5194/amt-10-2323-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.
Research article
27 Jun 2017
Consistency between GRUAN sondes, LBLRTM and IASI
Xavier Calbet1, Niobe Peinado-Galan2, Pilar Rípodas1, Tim Trent3,4, Ruud Dirksen5, and Michael Sommer5 1AEMET, C/Leonardo Prieto Castro, 8, Ciudad Universitaria, 28071 Madrid, Spain
2University of Valencia, Physics Faculty, Carrer del Dr. Moliner, 50, 46100 Burjassot, Valencia, Spain
3Earth Observation Science, Department of Physics and Astronomy, University of Leicester, University Road, Leicester, LE1 7RH, UK
4National Centre for Earth Observation, Department of Physics and Astronomy, University of Leicester, University Road, Leicester, LE1 7RH, UK
5Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg, Richard-Aßmann-Observatorium, Am Observatorium 12, 15848 Lindenberg/Tauche, Germany
Abstract. Radiosonde soundings from the GCOS Reference Upper-Air Network (GRUAN) data record are shown to be consistent with Infrared Atmospheric Sounding Instrument (IASI)-measured radiances via LBLRTM (Line-By-Line Radiative Transfer Model) in the part of the spectrum that is mostly affected by water vapour absorption in the upper troposphere (from 700 hPa up). This result is key for climate data records, since GRUAN, IASI and LBLRTM constitute reference measurements or a reference radiative transfer model in each of their fields. This is specially the case for night-time radiosonde measurements. Although the sample size is small (16 cases), daytime GRUAN radiosonde measurements seem to have a small dry bias of 2.5 % in absolute terms of relative humidity, located mainly in the upper troposphere, with respect to LBLRTM and IASI. Full metrological closure is not yet possible and will not be until collocation uncertainties are better characterized and a full uncertainty covariance matrix is clarified for GRUAN.

Citation: Calbet, X., Peinado-Galan, N., Rípodas, P., Trent, T., Dirksen, R., and Sommer, M.: Consistency between GRUAN sondes, LBLRTM and IASI, Atmos. Meas. Tech., 10, 2323-2335, https://doi.org/10.5194/amt-10-2323-2017, 2017.
Publications Copernicus
Download
Short summary
GRUAN temperature and water vapour radiosonde measurements are shown to be consistent with infrared hyperspectral measurements from IASI using LBLRTM as a reference radiative transfer model. Long-term climate data records of temperature and water vapour can be derived from radiosonde measurements and from space-based instruments. In order to have accurate and homogeneously useful data series, it is a critical necessary condition that these data sets be consistent with each other.
GRUAN temperature and water vapour radiosonde measurements are shown to be consistent with...
Share