Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.400 IF 3.400
  • IF 5-year value: 3.841 IF 5-year
    3.841
  • CiteScore value: 3.71 CiteScore
    3.71
  • SNIP value: 1.472 SNIP 1.472
  • IPP value: 3.57 IPP 3.57
  • SJR value: 1.770 SJR 1.770
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 70 Scimago H
    index 70
  • h5-index value: 49 h5-index 49
Volume 10, issue 12
Atmos. Meas. Tech., 10, 4687-4696, 2017
https://doi.org/10.5194/amt-10-4687-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 4.0 License.
Atmos. Meas. Tech., 10, 4687-4696, 2017
https://doi.org/10.5194/amt-10-4687-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 4.0 License.

Research article 04 Dec 2017

Research article | 04 Dec 2017

Effects of gas–wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

Demetrios Pagonis et al.
Viewed  
Total article views: 1,862 (including HTML, PDF, and XML)
HTML PDF XML Total Supplement BibTeX EndNote
1,068 773 21 1,862 205 28 47
  • HTML: 1,068
  • PDF: 773
  • XML: 21
  • Total: 1,862
  • Supplement: 205
  • BibTeX: 28
  • EndNote: 47
Views and downloads (calculated since 01 Aug 2017)
Cumulative views and downloads (calculated since 01 Aug 2017)
Viewed (geographical distribution)  
Total article views: 1,848 (including HTML, PDF, and XML) Thereof 1,839 with geography defined and 9 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Cited  
Saved (final revised paper)  
No saved metrics found.
Saved (discussion paper)  
No saved metrics found.
Discussed (final revised paper)  
No discussed metrics found.
Discussed (discussion paper)  
No discussed metrics found.
Latest update: 15 Jul 2019
Publications Copernicus
Download
Short summary
Laboratory studies were conducted to investigate gas-wall partitioning of atmospheric organic compounds in Teflon tubing and inside an instrument used to monitor concentrations. Rapid partitioning caused time delays in instrument response that vary with tubing length and diameter, flow rate, and compound volatility. Tubing delay times of seconds to hours were described using a model that also included effects of instrument surfaces. The results can enable better design of air sampling systems.
Laboratory studies were conducted to investigate gas-wall partitioning of atmospheric organic...
Citation