Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.400 IF 3.400
  • IF 5-year value: 3.841 IF 5-year
    3.841
  • CiteScore value: 3.71 CiteScore
    3.71
  • SNIP value: 1.472 SNIP 1.472
  • IPP value: 3.57 IPP 3.57
  • SJR value: 1.770 SJR 1.770
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 70 Scimago H
    index 70
  • h5-index value: 49 h5-index 49
AMT | Articles | Volume 11, issue 8
Atmos. Meas. Tech., 11, 4737–4756, 2018
https://doi.org/10.5194/amt-11-4737-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.

Special issue: The Polar Stratosphere in a Changing Climate (POLSTRACC) (ACP/AMT...

Atmos. Meas. Tech., 11, 4737–4756, 2018
https://doi.org/10.5194/amt-11-4737-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.

Research article 14 Aug 2018

Research article | 14 Aug 2018

Airborne limb-imaging measurements of temperature, HNO3, O3, ClONO2, H2O and CFC-12 during the Arctic winter 2015/2016: characterization, in situ validation and comparison to Aura/MLS

Sören Johansson et al.
Viewed  
Total article views: 1,364 (including HTML, PDF, and XML)
HTML PDF XML Total Supplement BibTeX EndNote
917 372 75 1,364 124 30 19
  • HTML: 917
  • PDF: 372
  • XML: 75
  • Total: 1,364
  • Supplement: 124
  • BibTeX: 30
  • EndNote: 19
Views and downloads (calculated since 08 Mar 2018)
Cumulative views and downloads (calculated since 08 Mar 2018)
Viewed (geographical distribution)  
Total article views: 1,342 (including HTML, PDF, and XML) Thereof 1,328 with geography defined and 14 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Cited  
Saved (final revised paper)  
No saved metrics found.
Saved (discussion paper)  
No saved metrics found.
Discussed (final revised paper)  
No discussed metrics found.
Discussed (discussion paper)  
No discussed metrics found.
Latest update: 17 Nov 2019
Publications Copernicus
Download
Short summary
We present two-dimensional cross sections of temperature, HNO3, O3, ClONO2, H2O and CFC-12 from measurements of the GLORIA infrared limb imager during the POLSTRACC/GW-LCYCLE/SALSA aircraft campaigns in the Arctic winter 2015/2016. GLORIA sounded the atmosphere between 5 and 14 km with vertical resolutions of 0.4–1 km. Estimated errors are in the range of 1–2 K (temperature) and 10 %–20 % (trace gases). Comparisons to in situ instruments onboard the aircraft and to Aura/MLS are shown.
We present two-dimensional cross sections of temperature, HNO3, O3, ClONO2, H2O and CFC-12 from...
Citation