Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
  • CiteScore<br/> value: 3.59 CiteScore
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
Atmos. Meas. Tech., 11, 861-879, 2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
Research article
14 Feb 2018
Three-channel single-wavelength lidar depolarization calibration
Emily M. McCullough1,2, Robert J. Sica1, James R. Drummond2, Graeme J. Nott2,a, Christopher Perro2, and Thomas J. Duck2 1Department of Physics and Astronomy, The University of Western Ontario, 1151 Richmond St., London, ON, N6A 3K7, Canada
2Department of Physics and Atmospheric Science, Dalhousie University, 6310 Coburg Rd., P.O. Box 15000, Halifax, NS, B3H 4R2, Canada
acurrently at: Facility for Airborne Atmospheric Measurements, Building 146, Cranfield University, Cranfield, MK43 0AL, UK
Abstract. Linear depolarization measurement capabilities were added to the CANDAC Rayleigh–Mie–Raman lidar (CRL) at Eureka, Nunavut, in the Canadian High Arctic in 2010. This upgrade enables measurements of the phases (liquid versus ice) of cold and mixed-phase clouds throughout the year, including during polar night. Depolarization measurements were calibrated according to existing methods using parallel- and perpendicular-polarized profiles as discussed in ). We present a new technique that uses the polarization-independent Rayleigh elastic channel in combination with one of the new polarization-dependent channels, and we show that for a lidar with low signal in one of the polarization-dependent channels this method is superior to the traditional method. The optimal procedure for CRL is to determine the depolarization parameter using the traditional method at low resolution (from parallel and perpendicular signals) and then to use this value to calibrate the high-resolution new measurements (from parallel and polarization-independent Rayleigh elastic signals). Due to its use of two high-signal-rate channels, the new method has lower statistical uncertainty and thus gives depolarization parameter values at higher spatial–temporal resolution by up to a factor of 20 for CRL. This method is easily adaptable to other lidar systems which are considering adding depolarization capability to existing hardware.

Citation: McCullough, E. M., Sica, R. J., Drummond, J. R., Nott, G. J., Perro, C., and Duck, T. J.: Three-channel single-wavelength lidar depolarization calibration, Atmos. Meas. Tech., 11, 861-879,, 2018.
Publications Copernicus
Short summary
Measuring the phase (liquid and ice) of Arctic clouds is essential for understanding the changing global climate. Using a lidar, two polarized signals are usually needed. At CRL lidar, one of these signals is small, so phase measurements have low resolution. Another method can use a large unpolarized signal in place of the small polarized signal. We show how to use the original low-resolution measurement to calibrate the new high-resolution method. At CRL, this gives 20 times higher resolution.
Measuring the phase (liquid and ice) of Arctic clouds is essential for understanding the...