Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.248 IF 3.248
  • IF 5-year value: 3.650 IF 5-year
    3.650
  • CiteScore value: 3.37 CiteScore
    3.37
  • SNIP value: 1.253 SNIP 1.253
  • SJR value: 1.869 SJR 1.869
  • IPP value: 3.29 IPP 3.29
  • h5-index value: 47 h5-index 47
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 60 Scimago H
    index 60
AMT | Articles | Volume 12, issue 3
Atmos. Meas. Tech., 12, 1935-1954, 2019
https://doi.org/10.5194/amt-12-1935-2019
© Author(s) 2019. This work is distributed under
the Creative Commons Attribution 4.0 License.
Atmos. Meas. Tech., 12, 1935-1954, 2019
https://doi.org/10.5194/amt-12-1935-2019
© Author(s) 2019. This work is distributed under
the Creative Commons Attribution 4.0 License.

Research article 26 Mar 2019

Research article | 26 Mar 2019

Chemical ionization quadrupole mass spectrometer with an electrical discharge ion source for atmospheric trace gas measurement

Philipp G. Eger et al.
Viewed  
Total article views: 812 (including HTML, PDF, and XML)
HTML PDF XML Total Supplement BibTeX EndNote
615 190 7 812 46 5 15
  • HTML: 615
  • PDF: 190
  • XML: 7
  • Total: 812
  • Supplement: 46
  • BibTeX: 5
  • EndNote: 15
Views and downloads (calculated since 19 Dec 2018)
Cumulative views and downloads (calculated since 19 Dec 2018)
Viewed (geographical distribution)  
Total article views: 514 (including HTML, PDF, and XML) Thereof 512 with geography defined and 2 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Cited  
Saved (final revised paper)  
No saved metrics found.
Saved (discussion paper)  
No saved metrics found.
Discussed (final revised paper)  
No discussed metrics found.
Discussed (discussion paper)  
No discussed metrics found.
Latest update: 23 May 2019
Publications Copernicus
Download
Short summary
We present a chemical ionization quadrupole mass spectrometer (CI-QMS) with a novel discharge ion source. In addition to the expected detection of PAN, peracetic acid and ClNO2, the instrument is also sensitive to SO2, HCl and acetic acid through ion chemistry unique for our ion source. We present ionization schemes along with illustrative datasets from field campaigns underlining the potential of the CI-QMS as an alternative to polonium, especially for application in the marine boundary layer.
We present a chemical ionization quadrupole mass spectrometer (CI-QMS) with a novel discharge...
Citation