Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.400 IF 3.400
  • IF 5-year value: 3.841 IF 5-year
    3.841
  • CiteScore value: 3.71 CiteScore
    3.71
  • SNIP value: 1.472 SNIP 1.472
  • IPP value: 3.57 IPP 3.57
  • SJR value: 1.770 SJR 1.770
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 70 Scimago H
    index 70
  • h5-index value: 49 h5-index 49
Volume 3, issue 1
Atmos. Meas. Tech., 3, 67–77, 2010
https://doi.org/10.5194/amt-3-67-2010
© Author(s) 2010. This work is distributed under
the Creative Commons Attribution 3.0 License.
Atmos. Meas. Tech., 3, 67–77, 2010
https://doi.org/10.5194/amt-3-67-2010
© Author(s) 2010. This work is distributed under
the Creative Commons Attribution 3.0 License.

  22 Jan 2010

22 Jan 2010

Water vapor δ2H and δ18O measurements using off-axis integrated cavity output spectroscopy

P. Sturm1 and A. Knohl2,1 P. Sturm and A. Knohl
  • 1Institute of Plant, Animal and Agroecosystem Sciences, ETH Zürich, Universitätsstrasse 2, 8092 Zürich, Switzerland
  • 2Chair of Bioclimatology, Georg-August University of Göttingen, Büsgenweg 2, 37077 Göttingen, Germany

Abstract. We present a detailed assessment of a commercially available water vapor isotope analyzer (WVIA, Los Gatos Research, Inc.) for simultaneous in-situ measurements of δ2H and δ18O in water vapor. This method, based on off-axis integrated cavity output spectroscopy, is an alternative to the conventional water trap/isotope ratio mass spectrometry (IRMS) techniques. We evaluate the analyzer in terms of precision, memory effects, concentration dependence, temperature sensitivity and long-term stability. A calibration system based on a droplet generator is used to characterize the performance and to calibrate the analyzer. Our results show that the precision at an averaging time of 15 s is 0.16‰ for δ2H and 0.08‰ for δ18O. The isotope ratios are strongly dependent on the water mixing ratio of the air. Taking into account this concentration dependence as well as the temperature sensitivity of the instrument we obtained a long-term stability of the water isotope measurements of 0.38‰ for δ2H and 0.25‰ for δ18O. The accuracy of the WVIA was further assessed by comparative measurements using IRMS and a dew point generator indicating a linear response in isotopic composition and H2O concentrations. The WVIA combined with a calibration system provides accurate high resolution water vapor isotope measurements and opens new possibilities for hydrological and ecological applications.