Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
    3.700
  • CiteScore<br/> value: 3.59 CiteScore
    3.59
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
Atmos. Meas. Tech., 5, 631-646, 2012
https://doi.org/10.5194/amt-5-631-2012
© Author(s) 2012. This work is distributed under
the Creative Commons Attribution 3.0 License.
Research article
27 Mar 2012
1D-Var retrieval of daytime total columnar water vapour from MERIS measurements
R. Lindstrot1, R. Preusker1, H. Diedrich1, L. Doppler1, R. Bennartz2, and J. Fischer1 1Institut für Weltraumwissenschaften, Freie Universität Berlin, Carl-Heinrich-Becker-Weg 6–10, 12165 Berlin, Germany
2Department of Atmospheric and Oceanic Sciences, University of Wisconsin-Madison, 1225 W. Dayton Street, Madison, WI, USA
Abstract. A new scheme for the retrieval of total columnar water vapour from measurements of MERIS (Medium Resolution Imaging Spectrometer) on ENVISAT (ENVIronmental SATellite) is presented. The algorithm is based on a fast forward model of the water vapour transmittance around 900nm, including a correction for atmospheric scattering and the influence of the temperature- and pressure-profile on the water vapour absorption lines. It provides the water vapour column amount for cloud-free scenes above land and ocean at a spatial resolution of 0.25 km × 0.3 km and 1 km × 1.2 km, depending on whether applied to the "full resolution" or the operational "reduced resolution" mode of MERIS. Uncertainties are provided on a pixel-by-pixel basis, taking into account all relevant sources of error. An extensive validation against various sources of ground-based reference data reveals a high accuracy of MERIS water vapour above land (root mean square deviations between 1.4 mm and 3.7 mm), apart from a wet bias of MERIS between 5 and 10% that is found in all comparison studies. This wet bias might be caused by spectroscopic uncertainties, such as the description of the water vapour continuum. Above ocean the accuracy is reduced, due to the uncertainty introduced by the unknown atmospheric scattering. Consequently, an increased root mean square deviation of ≥5 mm was found by comparing MERIS total columnar water vapour above ocean against SSM/I and ENVISAT MWR data. An increased wet bias of 2–3 mm is found over ocean, potentially due to a not properly working atmospheric correction scheme.

Citation: Lindstrot, R., Preusker, R., Diedrich, H., Doppler, L., Bennartz, R., and Fischer, J.: 1D-Var retrieval of daytime total columnar water vapour from MERIS measurements, Atmos. Meas. Tech., 5, 631-646, https://doi.org/10.5194/amt-5-631-2012, 2012.
Publications Copernicus
Download
Share