Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.668 IF 3.668
  • IF 5-year value: 3.707 IF 5-year
    3.707
  • CiteScore value: 6.3 CiteScore
    6.3
  • SNIP value: 1.383 SNIP 1.383
  • IPP value: 3.75 IPP 3.75
  • SJR value: 1.525 SJR 1.525
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 77 Scimago H
    index 77
  • h5-index value: 49 h5-index 49
Volume 5, issue 4
Atmos. Meas. Tech., 5, 735–757, 2012
https://doi.org/10.5194/amt-5-735-2012
© Author(s) 2012. This work is distributed under
the Creative Commons Attribution 3.0 License.
Atmos. Meas. Tech., 5, 735–757, 2012
https://doi.org/10.5194/amt-5-735-2012
© Author(s) 2012. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 18 Apr 2012

Research article | 18 Apr 2012

A modeling approach to evaluate the uncertainty in estimating the evaporation behaviour and volatility of organic aerosols

E. Fuentes and G. McFiggans E. Fuentes and G. McFiggans
  • Center for Atmospheric Science, School of Earth, Atmospheric and Environmental Sciences, Manchester, M13 9PL, UK

Abstract. The uncertainty in determining the volatility behaviour of organic particles from thermograms using calibration curves and a kinetic model has been evaluated. In the analysis, factors such as re-condensation, departure from equilibrium and analysis methodology were considered as potential sources of uncertainty in deriving volatility distribution from thermograms obtained with currently used thermodenuder designs.

The previously found empirical relationship between C* (saturation concentration) and T50 (temperature at which 50% of aerosol mass evaporates) was theoretically interpreted and tested to infer volatility distributions from experimental thermograms. The presented theoretical analysis shows that this empirical equation is in fact an equilibrium formulation, whose applicability is lessened as measurements deviate from equilibrium. While using a calibration curve between C* and T50 to estimate volatility properties was found to hold at equilibrium, significant underestimation was obtained under kinetically-controlled evaporation conditions. Because thermograms obtained at ambient aerosol loading levels are most likely to show departure from equilibrium, the application of a kinetic evaporation model is more suitable for inferring volatility properties of atmospheric samples than the calibration curve approach; however, the kinetic model analysis implies significant uncertainty, due to its sensitivity to the assumption of "effective" net kinetic evaporation and condensation coefficients. The influence of re-condensation on thermograms from the thermodenuder designs under study was found to be highly dependent on the particular experimental condition, with a significant potential to affect volatility estimations for aerosol mass loadings >50 μg m−3 and with increasing effective kinetic coefficient for condensation and decreasing particle size. These results show that the geometry of current thermodenuder systems should be modified to prevent re-condensation.

Publications Copernicus
Download
Citation