Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.248 IF 3.248
  • IF 5-year value: 3.650 IF 5-year 3.650
  • CiteScore value: 3.37 CiteScore 3.37
  • SNIP value: 1.253 SNIP 1.253
  • SJR value: 1.869 SJR 1.869
  • IPP value: 3.29 IPP 3.29
  • h5-index value: 47 h5-index 47
  • Scimago H index value: 60 Scimago H index 60
Volume 9, issue 7 | Copyright

Special issue: Atmospheric emissions from oil sands development and their...

Atmos. Meas. Tech., 9, 2961-2976, 2016
https://doi.org/10.5194/amt-9-2961-2016
© Author(s) 2016. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 14 Jul 2016

Research article | 14 Jul 2016

Sulfur dioxide (SO2) vertical column density measurements by Pandora spectrometer over the Canadian oil sands

Vitali E. Fioletov1, Chris A. McLinden1, Alexander Cede2,3, Jonathan Davies1, Cristian Mihele1, Stoyka Netcheva1, Shao-Meng Li1, and Jason O'Brien1 Vitali E. Fioletov et al.
  • 1Environment Canada and Climate Change Canada, Toronto, ON, Canada
  • 2NASA Goddard Space Flight Center, Greenbelt, MD, USA
  • 3LuftBlick, Kreith, Austria

Abstract. Vertical column densities (VCDs) of SO2 retrieved by a Pandora spectral sun photometer at Fort McKay, Alberta, Canada, from 2013 to 2015 were analysed. The Fort McKay site is located in the Canadian oil sands region, approximately 20km north of two major SO2 sources (upgraders), with total emission of about 45ktyr−1. Elevated SO2 VCD values were frequently recorded by the instrument, with the highest values of about 9Dobson Units (DU; DU  =  2.69 × 1016moleculescm−2). Comparisons with co-located in situ measurements demonstrated that there was a very good correlation between VCDs and surface concentrations in some cases, while in other cases, elevated VCDs did not correspond to high surface concentrations, suggesting the plume was above the ground. Elevated VCDs and surface concentrations were observed when the wind direction was from south to southeast, i.e. from the direction of the two local SO2 sources. The precision of the SO2 measurements, estimated from parallel measurements by two Pandora instruments at Toronto, is 0.17DU. The total uncertainty of Pandora SO2 VCD, estimated using measurements when the wind direction was away from the sources, is less than 0.26DU (1σ). Comparisons with integrated SO2 profiles from concurrent aircraft measurements support these estimates.

Publications Copernicus
Special issue
Download
Citation
Share